precision_manufacturingTurnkey Configured Water Plant Solution
Hospital & Pharmaceutical Ultrapure Water System (2,000 L/hr USP Purified Water)
Engineered turnkey configured solution designed for Ultrapure Water & Microelectronics. Standardizes delivery of high-purity product water while maximizing energy efficiency and operational reliability via pre-fabricated skids.
scheduleLead Time: ~12 Weeks DeliveryverifiedTurnkey Commissioning IncludedhubISO 9001 / ASME Standard
analyticsGuaranteed Operational Outcomes & Performance Limits
Capacity Range1,000 - 5,000 L/hr High PurityModular scalability
Delivery Timeline~12 WeeksFactory dispatch
Process IntegrationPre-tested Plug & PlayStandardized skids
Target AssetPharmaceutical Manufacturing, Hospitals, Biotech Labs & Semiconductor FabsCustomized baseline
view_moduleIncluded Modular Process Skids (5)
Fully skid-mounted and pre-piped in ISO containers01
Sanitary SS316L Pre-Treatment Skid
Factory integrated skid assembly (Stage 01) with instrumentation & PLC controls
checkFAT Tested in Factory
02
Dual RO Passes with Frequency Drives
Factory integrated skid assembly (Stage 02) with instrumentation & PLC controls
checkFAT Tested in Factory
03
EDI Ion Exchange Cell
Factory integrated skid assembly (Stage 03) with instrumentation & PLC controls
checkFAT Tested in Factory
04
TOC Reduction UV Lamp
Factory integrated skid assembly (Stage 04) with instrumentation & PLC controls
checkFAT Tested in Factory
05
0.1 μm Bacterial Filter
Factory integrated skid assembly (Stage 05) with instrumentation & PLC controls
checkFAT Tested in Factory
constructionIncluded Turnkey Engineering & Commissioning Scope
check_circleFDA/cGMP Installation Qualification (IQ)
check_circleOperational Qualification (OQ)
check_circle21 CFR Part 11 Audit Trail Compliance Verification
playlist_add_checkEngineering Design Assumptions
- Customer supplies concrete foundation slab and raw feed water connection.
- Customer supplies 400V / 3-phase / 50-60Hz electrical power boundary point.
- Raw water conditions comply with specified design envelope TDS limits.
warningExplicit Battery Limit Exclusions
- Off-site raw water intake civil structures and long-distance conveyance piping.
- Local environmental permit filing fees (technical dossier supplied by HydroPonds).